English
Bahasa indonesia
ไทย
日本語
Italiano
Deutsch
Français
Pусский
Português
Español
العربية
简体中文

Products Category

Products

UL Door Hardware

CE Door Hardware

Fire Rated Door Hardware

Door Hinge

Fire Rated Door Hinge UL Listed

ANSI Fire Rated Door Hinge

BS EN 1935 Grade 13 CE Hinge

Heavy Duty Hinges

Electrified Door Hinge

Flag Hinge

Stainless Steel Hinges

Lift-Off Hinge

Spring Hinge

Flush Hinges

Security Hinge

Antirust Door Hinge

Folding Door Hinge

Commercial Hinges

Continuous Piano Hinge

Shower Door Hinge

Hinge Screw

Brass Hinge

Concealed Door Hinge

EN1935 Invisible Hinge

UL Concealed Hinge

Adjustable Concealed Hinge

Concealed Hinge

Door Lock

Fire Door Lock

CE Mortise Lock

Euro Mortise Lock

Dead Bolt Lock

Door Lock for Front Door

Bathroom Door Lock

Door Lock for Sliding Door

Narrow Stile Lock

Commercial Door Lock

Door Lock for Classroom

Passage Door Lock

ANSI Mortise Lock

Tubular Lock

Cylindrical Lock

Door Lock Cylinder

Lock Cylinder EN1303

Lock Cylinder

Lock Cylinder ANSI

Panic Exit Hardware

UL Fire Exit Hardware

CE Panic Hardware

Commercial Door Push Bar

Panic Exit Device Lever Trim

Door Control

UL Door Closer

CE Door Closer

Door Closer

Concealed Door Closer

Heavy Duty Door Closer

Security Door Controls 

Door Selector

Door Coordinator

Pneumatic Door Closer

Door Handle

EN1906 Lever Handle

Tube Lever Handle-Hollow

Solid Door Handle

ANSI Door Handle

Door Handle on plate

Stainless Steel Lever

Antirust Door Handle

Lever Handle for Narrow Frame

Door knob

Lever on Backplate

Door Pull Handle

Glass door handle

Shower Door Handle

Escutcheon

Bathroom Hardware

Bathroom Mortise Lock

Bathroom Lock Cylinder

Toilet Indicator

Thumb turn with indicator

Bathroom Accessories

Door Bolt

Lever Action Flush Bolt

Wooden door bolt

Metal door flush bolts

Door Latch

Security Door Bolts

Stainless Steel Indicator Bolt

Dust Proof Socket

Flush Bolt for Metal Door

Flush Bolt for Wooden Door

Door Stopper

Door Holder

Floor Mounted Doorstop

Wall Mounted Door Stops

Magnetic Door Holders

Foot operated Door Holder

Bifold Door Catch Kit

Digital Door Lock

Padlock

Rim Lock

Door Accessories

Door Chain

Door Guard

Door Viewer

Sign Plate

Ball Catch

Push Pull Plate

Kick Plate

Metal Door Accessories

Intumescent Pads

Glass Hardware

Glass Door Hinge

Patch Fitting

Floor Spring

Glass Clip

Barn Door Hardware

Furniture Hardware

Furniture Handle

Cabinet Pulls

Cabinet knob

Towel Coat Hook

Automatic Door Drop Seal

Hands Free Door Opener


 :  +86-750-3652251 / 3856396

:  +86-750-3856395 / 3856397

www.dndhardware.com

:  sales@dndhardware.com

 

How to Verify UL Listed Door Hardware and Its UL File Number

Publish Time: 2026-09-23     Origin: D&D Hardware


A UL file number helps you find a certification record; it does not certify every model in a supplier’s catalog. To verify UL listed door hardware, match the exact model to the current UL record, its product category, applicable standard, rating and installation conditions. This check matters most when a hardware set is being submitted for a fire rated commercial door.


Start with the product, then check the file

Record the model designation from the hardware schedule, product label and manufacturer’s drawing. Include relevant variants such as size, function, finish and handing where the certification differentiates them. Ask for the UL file number and the applicable standard for that specific configuration. A brochure image or a statement that a product is “UL approved” is insufficient for model level verification.

Open UL Solutions’ Product iQ and search by file number or model. Product iQ also supports company names and category descriptions, including Category Control Numbers (CCNs). Review the company and product category shown in the result, then read the certification details for the model or series being proposed. A single file may include more than one model; a valid file number alone does not establish that a particular substitute is covered.

Compare the certification record with the submitted product marking, drawings and installation instructions. Confirm the stated fire rating and any restrictions on size, mounting or use. If the model or condition cannot be reconciled, request the applicable listing detail from the manufacturer before approving the submittal.



Understand what UL 10C and UL 305 establish

UL 10C is the standard for positive pressure fire tests of door assemblies. The presence of “UL 10C” in marketing copy does not automatically give every hardware model a three hour rating. Read the relevant certification and its conditions for the actual opening. UL 305 is the standard for panic hardware and concerns the exit device’s egress function. UL’s door and hardware guidance says fire exit hardware must meet both UL 305 and UL 10C. A UL 305 panic device should therefore not be assumed suitable for a fire rated opening without confirming its fire exit hardware certification.


D&D certification references to check

As a fire door hardware manufacturer, we provide the following file references as starting points for reviewing our applicable models. Verify each selected model and its current certification scope in Product iQ before specifying it:

Product

Standard and   stated rating

File reference

Door hinge

UL/cUL UL 10C, up to 3 hours

R38013;   ANSI/BHMA Grade 1 or Grade 2 as applicable

Concealed door hinge

UL 10C

R38013

Door lock

UL 10C, up to 3 hours

R40901

Door closer

UL 10C, up to 3 hours

R40717

Fire exit hardware

UL 10C, up to 3 hours

R40486; also   check applicable UL 305 coverage

Panic hardware

UL 305

SA45817

These references identify certification files, not a blanket approval of every D&D item. For a concealed hinge, for example, confirm its particular model under R38013 rather than applying the certification of another hinge with a similar appearance. Check Grade 1 or Grade 2 performance claims separately against the applicable ANSI/BHMA documentation; cycle grade and fire certification answer different questions.



When records are difficult to interpret, keep the question narrow: does the listing cover this exact item on this type of opening? An opening may involve a labeled door and frame, a latch, hinges, a closer and an exit device. Certification for one component cannot establish compliance of the complete assembly. The specified door rating, hardware preparation and installation instructions must also align. Where a project requires a particular regional mark, such as cUL, confirm that geographic scope in the certification and marking rather than inferring it from a general UL reference.




What to include in a technical submittal

For each opening, provide the exact model, product category, UL file number, applicable standard, certified rating where relevant, and a drawing or data sheet that identifies the supplied configuration. Add the manufacturer’s installation instructions and photographs of the required product marking when requested. For an exit door, distinguish panic hardware from fire exit hardware on the schedule. This makes the certification trail reviewable by the door manufacturer, consultant and authority having jurisdiction.


Frequently asked questions


How do I check a UL file number? 

Search it in UL Product iQ, open the relevant record and match the manufacturer, category and exact model to the hardware being supplied. Then check the standard, rating and stated limitations.

Can one file number cover several models? 

Yes. Coverage is defined by the certification record. Similar products outside its listed scope cannot borrow the same claim.

Does UL 10C mean the hinge is rated for three hours? 

No. UL 10C identifies a fire test standard. Confirm the rating and permitted application in the specific certification record and door assembly documentation.

Is UL 305 enough for a fire rated exit door? 

No. UL guidance identifies both UL 305 and UL 10C for fire exit hardware. Verify the device’s actual fire exit listing and its use on the intended opening.

What if the supplied model differs from the submitted model? 

Treat it as a substitution. Check the replacement model’s current certification scope, configuration and installation conditions before accepting it.


When you send us a door schedule, we can identify the proposed D&D models and provide their corresponding certification references and technical documents for review. Final acceptance should be based on the current UL record and the complete door assembly requirements.


Contact us Now:


Contact: David Jian

Mob:0086-139 2903 7292

Email: David@dndhardware.com, sales@dndhardware.com,


Contact: Jobby Zhang

Mob:0086-137 2599 9617

Email: jobby@dndhardware.com


D&D HARDWARE INDUSTRIAL CO.,LTD  

ADD:12th Floor, Building 2, No.898, KeChuang Technical Zone, Jiangmen Avenue, Pengjiang District, Jiangmen City, Guangdong, China (Postcode:529000)

https://www.dndhardware.com

Tel: +86-750-3856396

Fax: +86-750-3856395


Contact Info

:+86-139 2903 7292   David Jian

:  +86-750- 3856396

 : sales@dndhardware.com
 
: +86-139 2903 7292
 
 : +86-139 2903 7292

:  12th Floor, Building 2, No.898, KeChuang Technical Zone,
Jiangmen Avenue, Pengjiang District, Jiangmen City, Guangdong, China
Get Famous Branded Quality at Factory Cost