Get Famous Branded Quality at Factory Cost

Products Category

Products

UL Door Hardware

CE Door Hardware

Fire Rated Door Hardware

Door Hinge

Fire Rated Door Hinge UL Listed

ANSI Fire Rated Door Hinge

BS EN 1935 Grade 13 CE Hinge

Heavy Duty Hinges

3D Adjustable Concealed Hinge

Concealed Hinge

Electrified Door Hinge

Flag Hinge

Stainless Steel Hinges

Lift-Off Hinge

Spring Hinge

Flush Hinges

Security Hinge

Antirust Door Hinge

Folding Door Hinge

Commercial Hinges

Continuous Piano Hinge

Shower Door Hinge

Hinge Screw

Brass Hinge

Stainless Steel Door Hinge-UL Listed

Hinge Screw & ANSI Screw

Door Lock

Fire Door Lock

CE Mortise Lock

Euro Mortise Lock

Dead Bolt Lock

Door Lock for Front Door

Bathroom Door Lock

Door Lock for Sliding Door

Narrow Stile Lock

Commercial Door Lock

Door Lock for Classroom

Passage Door Lock

ANSI Mortise Lock

ANSI Tubular Lock-set

Tubular Lock

Cylindrical Lock

Door Lock Cylinder

Lock Cylinder EN1303

Lock Cylinder

Lock Cylinder ANSI

Panic Exit Hardware

UL Fire Exit Hardware

CE Panic Hardware

Commercial Door Push Bar

Panic Exit Device Lever Trim

Door Control

UL Door Closer

Door Closer

Concealed Door Closer

Heavy Duty Door Closer

Security Door Controls 

Door Selector

Door Coordinator

CE Door Closer

Door Hardware

Door Handle

EN1906 Lever Handle

Tube Lever Handle-Hollow

Solid Door Handle

ANSI Door Handle

Door Handle on plate

Stainless Steel Lever

Antirust Door Handle

Lever Handle for Narrow Frame

Door knob

Lever on Backplate

Door Pull Handle

Glass door handle

Shower Door Handle

Escutcheon

Tube Lever Handle-Plastic Base

Door Pull Handle With Lock

Bathroom Hardware

Bathroom Mortise Lock

Bathroom Lock Cylinder

Toilet Indicator

Thumb turn with indicator

Bathroom Accessories

Door Bolt

Lever Action Flush Bolt

Wooden door bolt

Metal door flush bolts

Door Latch

Security Door Bolts

Stainless Steel Indicator Bolt

Dust Proof Socket

Flush Bolt for Metal Door

Flush Bolt for Wooden Door

Door Stopper

Door Holder

Floor Mounted Doorstop

Wall Mounted Door Stops

Magnetic Door Holders

Foot operated Door Holder

Bifold Door Catch Kit

Digital Door Lock

Padlock

Door Accessories

Door Chain

Door Guard

Door Viewer

Sign Plate

Ball Catch

Push Pull Plate

Kick Plate

Metal Door Accessories

Intumescent Pads

Hardware Fittings

Glass Hardware

Glass Door Hinge

Patch Fitting

Floor Spring

Glass Clip

Sliding Door Hardware

Sliding Door Lock

Sliding Door Hinge

Sliding Door Bolt

Sliding Accessories

Barn Door Hardware

Furniture Hardware

Furniture Handle

Cabinet Pulls

Cabinet knob

Towel Coat Hook

Hands Free Door Opener


 :  +86-750-3652251 / 3856396

:  +86-750-3856395 / 3856397

www.dndhardware.com

:  sales@dndhardware.com

 

Door hardware for fire-rated openings

Publish Time: 2022-02-12     Origin: D&D Hardware

Fire-rated openings are used to compartmentalize a building or space to prevent the spread of flame, smoke and toxic gases. The 2019 edition of NFPA 80, Standard for Fire Doors and Other Opening Protectives, establishes the criteria that fire-rated doors and frames must meet.

NFPA 80 requires side hinged and pivoted fire-rated doors and frames to be tested in accordance with established testing methods and procedures listed in NFPA 252, Standard Methods of Fire Test of Door Assemblies.


General Requirements for fire-rated openings

Chapter 4 of NFPA 80 covers the general requirements for all types of fire-rated assemblies. It defines the requirements for hardware preparations, glazing limitations, classifications of hardware for fire doors, and sills.

Fire-rated door assemblies consist of a:

Fire-rated frame

Fire-rated door

Labeled/Listed hanging device.

Labeled latching device.

Listed door closing device.


Remark: Mechanical hold-open devices are not permitted to be used on fire-rated openings.


Labeled/Listed hanging device:

Labeled conventional hinges installed on fire-rated doors must be made from steel(ferrous) or stainless-steel metals. Ball bearing or antifriction bearing hinges are required to be used to ensure that the doors swing easily. Labeled pivots and continuous hinges also have bearings that permits the doors to operate easily.

NFPA 80 requires fire-rated openings to have two conventional hinges on openings up to 60 inches in height. One additional hinge is required for each additional 30 inches of door height or fraction thereof.

Where spring hinges are used, at least two shall be provided, they are not required to be ball bearing, but shall be labeled.


Labeled latching device.

Latching devices on fire-rated doors must be labeled for use on fire-rated assemblies. Latch bolts are not permitted to be mechanically held in the retracted position.

Locks with interconnected deadbolts that retract when the latch bolt is retracted shall be permitted for use on fire doors in a means of egress.

The throw of single point latch bolts shall not be less than the minimum shown on the label of the fire doors.

Fire exit hardware consists of exit devices that have been tested and labeled for use on fire-rated openings. A label is attached to fire exit hardware in compliance with NFPA 80. Unlike panic hardware, fire exit hardware is not permitted to be mechanically dogged open.

Fire-rated doors that are required to have an exit device will have labels that state “Fire Door to Be Equipped with Fire Exit Hardware.” Only exit devices that have been tested and labeled for use on fire-rated assemblies can be used. Typically, doors with this label have been internally reinforced to receive the fasteners that attach fire exit hardware to the doors.

Labeled manually operated flush and surface bolts are permitted to be used on the inactive leaf of a pair doors where acceptable by the AHJ. This provision limits their use to rooms not normally occupied such as transformer vaults and storage rooms.

Pairs of fire doors that are needed for the movement of equipment where the inactive leaf is not required for egress purposes, are required to have labeled automatic or self-latching flush bolts or labeled two-point latches.

Listed door closing device.

Fire-rated doors must be able to swing easily in order for door closers to efficiently close the doors. NFPA 80 separates the closing operation of doors into three categories:


1, Self-Closing

Door closers on self-closing fire-rated doors return the door to the closed position and cause the latch to engage the strike after each opening cycle of the door. The door closers are not permitted to have a hold-open mechanism.


2, Automatic -Closing

Automatic-closing fire-rated doors are held open, either by an electrified door closer or by hold-open devices such as wall magnets that automatically release immediately upon actuation of the fire alarm system or power failure. When power is removed, the door-holding device releases, allowing the closer to close the door.


3, Power Operated Fire Doors

Power-operated fired doors are doors that are normally opened and closed by operators. In the case of fire or a power failure. The operators must release and allow the doors to function manually.


For further information about fire door hardware or any of our services, click here.

Contact us Now:

Contact: David Jian

Mob: 0086-139 2903 7292

Email: David@dndhardware.com, sales@dndhardware.com

Jobby Zhang

Mob: 0086-137 2599 9617

Email: jobby@dndhardware.com

Contact Info

:+86-139 2903 7292   David Jian

:  +86-750- 3856396

 : sales@dndhardware.com
 
 
 : +86-139 2903 7292

:  12th Floor, Building 2, No.898, KeChuang Technical Zone,
Jiangmen Avenue, Pengjiang District, Jiangmen City, Guangdong, China
Get Famous Branded Quality at Factory Cost

©Copyright D&D HARDWARE INDUSTRIAL Co., LIMITED. All Rights Reserved.